Str. Dr. Louis Pasteur nr. 8, sector 5, 050535, Bucuresti, Romania 0214103182 0214103064 [email protected]

Battery Monitoring CELLGUARD™ ELS+

Print
Manufacturer: Franklin-Electric show products
Hits: 409

 Description

The CELLGUARD™ ELS+ - Electrolyte Level Monitoring System provides reliable electrolyte level monitoring on Vented Lead Acid (VLA) batteries of any voltage, size, or design in Utility, Telecommunications, Data Centers, and Industrial Battery Plant applications.

SAFE & EFFECTIVE VLA BATTERY MONITORING - The CELLGUARD™ ELS+ Electrolyte Level Monitoring System is completely non-invasive to VLA batteries and enhances operational safety with24/7 monitoring of electrolyte levels.

KEY ADVANTAGES

 
MONITORING CAPABILITIES - During a low level electrolyte level condition the sensor communicates an alarm condition to the hub unit. The hub senses the alarm state and provides a dry contact alarm\lead status.
VISUAL ALARM - Both the sensors and hub units provide LED indication to visually identify VLA batteries that require servicing.
NERC PRC-005 COMPLIANCE - Complies with NERC PRC-005 electrolyte level inspection requirements with 24/7 alarm reporting.
EASY INSTALATION - Modular quick connect cabling provides time-saving installation without the need for a site survey.
EASY TO INSTALL, EASY TO CONFIGURE - The CELLGUARD™ ELS+ Electrolyte Level Monitoring System can monitor up to 600 batteries per hub. Multiple hub inputs can be used on a single battery string to monitor all the cells within the battery string.
 

ELS+ Sensor

Battery Types Vented Lead-Acid (VLA) battery
Alarm Leads Active Open, via RJ25 jack connection
Alarm Activation (Electrolyte Level) Activation when level is below ± 2 mm of calibrated reference
Response time: 4 minutes
LED Status Indicator Flashing Green (normal state), Flashing Red (alarm state),
Amber (non-calibrated)
Power Input 12V dc ± 2V dc at 2.5 mA Typical, via RJ25 jack
CG-ELS+ HUB connection
Operating Temperature Range -10 to 65° C
Storage Temperature Range -20 to 70° C
Dimensions 2.60” W X 2.60” D x 1.00” H
(66.04 mm W x 66.04 mm D x 25.4 mm H)
Enclosure 94V-0 ABS Plastic Housing
Mounting 3M Adhesive Tape
Maximum Case Thickness for Level Sensor 1/2” (non-opaque)

ELS+ Alarm Hub

Battery Strings Up to 4 CG-ELS+ Sensor strings containing 2, 4, 6, and 8 Volt batteries
Input Configurations Flexible Configuration, typically 24, 48, 110/120, 220/240 and 480 Volt systems
ELS+ Sensor Arrangement 600 CG-ELS+ Sensors per CG-ELS+ HUB with 150 maximum
CG-ELS+ Sensors for each of the 4 CG-ELS+ HUB inputs
Multiple CG-ELS+ HUB Inputs can be used on a single battery string to monitor all the cells within the battery string
Alarm Output 2 Form C Dry Contacts, 1A
Duplicate connector pins for alarm aggregation from multiple Hub units
LED Status Indicator Green (normal state), Red (alarm state)
Power Input 120V/240V AC 50/60 Hz AC Wall Adapter to 12 VDC at 2 Amps max
Power Status LED Green when module power is on
Operating Temperature Range -10 to 65° C
Storage Temperature Range -20 to 70° C
Dimensions 3.972” W x 2.023” D x 0.876” H
(100.9 mm W x 51.40 mm D x 22.25 mm H)
Enclosure 94V-0 ABS Plastic Housing
Mounting Cable Tie Brackets or Free Standing
 