With a usable frequency range of 10 KHz to 152 MHz the BCP-611 monitoring current probe is a great measurement tool for MIL-STD, CISPR and many automotive specifications. The 1V/A flat response of this current probe makes it ideal for a 1:1 comparison for conducted emission measurement and troubleshooting applications.
The BCP-611 is designed to make conducted current measurements without making direct contact with the source conductor or metallic surface. It has a usable frequency range of 10 KHz to 150 MHz with a constant transfer impedance of 1 ohm from 1 MHz to 80 MHz. This flat response makes for an easy interpretation of spectrum analyzer or receiver reading in dBV to conducted emission limit in dBA. Another application of a constant transfer impedance is the ability to make useful time domain measurements i.e. oscilloscope traces of current waveform. This is extremely useful where pulsed current must be measured, as in inrush current measurements.
With a 1.25” aperture, the BCP-611 current probe can easily measure most power cables and wire bundles carrying up to 4 amps. Core saturation can occur if the 60 Hz, 400Hz power line or CW limits are exceeded. For those cases where for an increased current capability then consider the BCP-615 or when a larger aperture is required consider the BCP-614.
For ease and convenience of performing conducted measurements, all of our current probes utilize the split type clamp-on design. Small and lightweight, each Current Probe is manufactured to exacting standards, thus insuring repeatable performance.
RECOMMENDED ACCESSORIES
Injection Probe calibration fixtures are a part of the test equipment required by most of the Bulk current Injection Test Procedure Specifications. The Calibration Fixture allows the user to quickly and easily calibrate the injection probe prior to performing the compliance testing. It exceeds DO-160, Section 20 VSWR fixture requirements for stand-alone injection probe calibration fixture.
3 Meter RF cable with N(m) to N(m) connectors. Custom lengths can be made to suit your specifications.
Rugged polyethylene case that includes a custom foam cutout for the current probes.
Frequency Range: | 10 KHz - 150 MHz |
Transfer Impedance (dBohm) | -25 to +5 |
Max Primary Current (DC - 60 Hz) |
800 Amps |
Max Primary Current (400 Hz) |
450 Amps |
Max Primary Current CW | 4 Amps |
Peak Pulse Current | 100 Amps |
Connector: | BNC-Type, Female |
Physical Dimensions | |
Aperture: | 1.25" (32 mm) |
Weight: | 1.4 lb.'s (0.65 Kg) |