Str. Dr. Louis Pasteur nr. 8, sector 5, 050535, Bucuresti, Romania 0214103182 0214103064 [email protected]

Current Probes ICP-621 10 KHz - 100 MHz

Print
Manufacturer: A.H. Systems show products
Hits: 1046

Description

This injection current probe can be used as injection source as well as a sensitive monitoring probe.

Features

  • 10 KHz to 100 MHz
  • Individually Calibrated
  • Rugged Construction
  • Three Year Warranty
  • MIL-STD-461 CS114

Product Details

The ICP-621 injection current probe is used for specifications that require the injection of large frequency currents into cable bundles and individual wires. It can be used as an injection source as well as a sensitive monitoring probe. The ICP-621 has an input power rating of 100 watts CW for 30 minutes and covers the frequency range of 10 KHz - 100 MHz.

An injection current probe acts as a multiple turn primary and a single turn secondary transformer, when placed around a power line or signal lead. Thus it provides a (nominal) 50ohm load to the susceptibility signal source, while providing a lower susceptibility signal source impedance when placed in series with the cable under test. An injection current probe is characterized by its insertion loss (dB). The insertion loss describes the inefficiency of the clamp relative to direct injection into a 50ohm circuit.

RECOMMENDED ACCESSORIES

CPF-630 - Current Probe Fixture

Injection Probe calibration fixtures are a part of the test equipment required by most of the Bulk current Injection Test Procedure Specifications. The Calibration Fixture allows the user to quickly and easily calibrate the injection probe prior to performing the compliance testing. It exceeds DO-160, Section 20 VSWR fixture requirements for stand-alone injection probe calibration fixture.

SAC-213 - 3 Meter N/N Cable

3 Meter RF cable with N(m) to N(m) connectors. Custom lengths can be made to suit your specifications.

SPECIFICATIONS

ICP-621
Frequency Range: 10 KHz - 100 MHz
Insertion Loss 8 to 30 dB
Max Input Power 100 watts
Max Input Current 26 Amps
Max Time at Full Power 30 minutes
Max Temperature Rise 35° C
Connector: N-Type, Female
Physical Dimensions  
Aperture: 1.5" (38 mm)
Diameter: 4.25" (108 mm)
Weight: 4.2 lb.'s (1.9 kg)
 

Attachments

Ask about this product